One-lung ventilation when intubation is difficult--presentation of a new endobronchial blocker.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 10081546.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
One-lung ventilation utilizing a double-lumen endotracheal tube may be technically difficult or inappropriate in morbidly obese or critically ill patients. In patients requiring awake fiberoptic intubation, double-lumen tube placement may be impossible. Wire-guided endobronchial blockade through a conventional endotracheal tube is a new alternative for these patients. A 44-year-old, 133 kg female patient was scheduled to undergo a thoracotomy for transthoracic fundoplication. A wire-guided endobronchial blocker (WEB) was placed following rapid-sequence induction and intubation with an 8.0 OD single-lumen endotracheal tube with the aid of a pediatric bronchoscope. The WEB, using a guiding loop, was placed with ease and allowed effective one-lung ventilation. The WEB system allows one-lung ventilation to be achieved with a conventional endotracheal tube. The need for reintubation at the end of surgery is eliminated and endotracheal tube cross-sectional area is conserved.
Medical subject headings
- Anesthesia
- Bronchi
- Intubation, Intratracheal
- Respiration, Artificial