Usefulness of D-dimer, blood gas, and respiratory rate measurements for excluding pulmonary embolism.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 10193368.
- Also identified by PMC identifier 1745091.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A study was undertaken to assess the usefulness of the SimpliRED D-dimer test, arterial oxygen tension, and respiratory rate measurement for excluding pulmonary embolism (PE) and venous thromboembolism (VTE). Lung scans were performed in 517 consecutive medical inpatients with suspected acute PE over a one year period. Predetermined end points for objectively diagnosed PE in order of precedence were (1) a post mortem diagnosis, (2) a positive pulmonary angiogram, (3) a high probability ventilation perfusion lung scan when the pretest probability was also high, and (4) the unanimous opinion of an adjudication committee. Deep vein thrombosis (DVT) was diagnosed by standard ultrasound and venography. A total of 40 cases of PE and 37 cases of DVT were objectively diagnosed. The predictive value of a negative SimpliRED test for excluding objectively diagnosed PE was 0.99 (error rate 2/249), that of PaO2 of > or = 80 mm Hg (10.7 kPa) was 0.97 (error rate 5/160), and that of a respiratory rate of < or = 20/min was 0.95 (error rate 14/308). The best combination of findings for excluding PE was a negative SimpliRED test and PaO2 > or = 80 mm Hg, which gave a predictive value of 1.0 (error rate 0/93). The predictive value of a negative SimpliRED test for excluding VTE was 0.98 (error rate 5/249). All three of these observations are helpful in excluding PE. When any two parameters were normal, PE was very unlikely. In patients with a negative SimpliRED test and PaO2 of > or = 80 mm Hg a lung scan is usually unnecessary. Application of this approach for triage in the preliminary assessment of suspected PE could lead to a reduced rate of false positive diagnoses and considerable resource savings.
Medical subject headings
- Antifibrinolytic Agents
- Fibrin Fibrinogen Degradation Products
- Pulmonary Embolism