Detection of hepatocellular carcinoma arising in cirrhotic livers: comparison of gadolinium- and ferumoxides-enhanced MR imaging.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 10350287.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We prospectively compared the detectability of hepatocellular carcinoma (HCC) arising in cirrhotic livers using dynamic gadolinium-enhanced fast low-angle shot (FLASH), ferumoxides-enhanced T2-weighted turbo spin-echo, and ferumoxides-enhanced T2*-weighted FLASH MR imaging. Fifty-three patients with HCC (32 men and 21 women) who were 33-86 years old (mean, 63 years old) were enrolled in a prospective MR study to assess hepatic lesions using both gadopentetate dimeglumine and ferumoxides. Dynamic gadolinium-enhanced imaging was obtained before and 30, 60, and 180 sec after rapid bolus injection of gadopentetate dimeglumine (0.1 mmol/kg). Ferumoxides-enhanced T2-weighted turbo spin-echo imaging and ferumoxides-enhanced T2*-weighted FLASH imaging were performed between 30 min and 2 hr after i.v. infusion of ferumoxides (10 micromol/kg). Images were analyzed qualitatively and quantitatively. A receiver operating characteristic curve study was performed to compare the diagnostic value of gadolinium-enhanced imaging with that of ferumoxides-enhanced imaging for the detection of HCC. Quantitative analysis revealed a significantly higher percentage of signal-intensity loss and higher liver-lesion contrast-to-noise ratio on ferumoxides-enhanced T2*-weighted FLASH imaging than on ferumoxides-enhanced T2-weighted turbo spin-echo imaging. The percentage of signal-intensity loss and liver-lesion contrast-to-noise ratio on ferumoxides-enhanced images was significantly higher in patients with mild liver cirrhosis (Child's class A) than in patients with severe liver cirrhosis (Child's class C). Qualitative analysis showed that dynamic gadolinium-enhanced images revealed significantly higher lesion conspicuity than did ferumoxides-enhanced T2-weighted turbo spin-echo images. According to receiver operating characteristic analysis, dynamic gadolinium-enhanced FLASH imaging achieved the highest sensitivity, and ferumoxides-enhanced T2*-weighted FLASH imaging was the second most sensitive. We found that ferumoxides-enhanced turbo spin-echo imaging was the least valuable technique for revealing HCC lesions. Gadolinium-enhanced imaging revealed more HCC lesions than did ferumoxides-enhanced imaging, particularly for lesions smaller than 2 cm in diameter. Ferumoxides-enhanced imaging revealed fewer findings, such as lesion conspicuity of HCCs arising in cirrhotic livers, than did gadolinium-enhanced FLASH imaging.
Medical subject headings
- Carcinoma, Hepatocellular
- Contrast Media
- Gadolinium DTPA
- Iron
- Liver Cirrhosis
- Liver Neoplasms
- Magnetic Resonance Imaging
- Oxides