Carotid arterial stenosis: evaluation at CT angiography with the volume-rendering technique.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 10352606.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To determine whether computed tomographic (CT) angiography with the volume-rendering technique (VRT) can be used to accurately quantify carotid arterial stenosis and to identify occlusions. Spiral CT was performed in 23 patients who were referred for carotid stenosis evaluation. VRT images and shaded-surface display (SSD) images of 46 carotid arterial bifurcations were compared with findings from digital subtraction angiography (DSA). Agreement on stenosis category between VRT CT angiography and DSA was found in 39 (85%) of the 46 carotid arteries studied. VRT CT angiography was 92% (49 of 53) sensitive and 96% (82 of 85) specific for the detection of grade 2-3 stenoses (> or = 70% stenosis). Agreement on stenosis category between SSD CT angiography and DSA was found in 38 (83%) of the 46 carotid arteries studied. SSD CT angiography was 91% (48 of 53) sensitive and 93% (79 of 85) specific for the detection of grade 2-3 stenoses. Calcified stenoses were correctly graded at VRT CT angiography in 10 of the 10 cases with heavy mural calcified plaques, while eight of the 10 stenoses were accurately quantified at SSD CT angiography. These results indicate that VRT CT angiography is as accurate as SSD CT angiography in the evaluation of carotid arterial bifurcations.
Medical subject headings
- Carotid Arteries
- Carotid Stenosis
- Tomography, X-Ray Computed