Epidural haematoma after removal of an epidural catheter in a patient receiving high-dose enoxaparin.

Yin, B; Barratt, S M; Power, I; Percy, J · Br J Anaesth · 1999

case_report · Level V

Where this comes from

Abstract

A patient developed an epidural haematoma 6 days after removal of an epidural catheter resulting in paraplegia and death. Insertion and removal of the epidural catheter during anticoagulation with prophylactic unfractionated heparin and subsequent administration of high-dose enoxaparin (Clexane), which commenced 3 days after catheter removal, were implicated.