Complementary clinical benefits of coronary-artery stenting and blockade of platelet glycoprotein IIb/IIIa receptors. Evaluation of Platelet IIb/IIIa Inhibition in Stenting Investigators.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 10423466.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Inhibition of the platelet glycoprotein IIb/IIIa receptor with the monoclonal-antibody fragment abciximab reduces the acute ischemic complications associated with percutaneous coronary revascularization, whereas coronary-stent implantation reduces restenosis. We conducted a trial to determine the efficacy of abciximab and stent implantation in improving long-term outcome. A total of 2399 patients were randomly assigned to stent implantation and placebo, stent implantation and abciximab, or balloon angioplasty and abciximab. The patients were followed for six months. At six months, the incidence of the composite end point of death or myocardial infarction was 11.4 percent in the group that received a stent and placebo, as compared with 5.6 percent in the group that received a stent and abciximab (hazard ratio, 0.47; 95 percent confidence interval, 0.33 to 0.68; P<0.001) and 7.8 percent in the group assigned to balloon angioplasty and abciximab (hazard ratio, 0.67; 95 percent confidence interval, 0.49 to 0.92; P=0.01). The hazard ratio for stenting plus abciximab as compared with angioplasty plus abciximab was 0.70 (95 percent confidence interval, 0.48 to 1.04; P=0.07). The rate of repeated revascularization of the target vessel was 10.6 percent in the stent-plus-placebo group, as compared with 8.7 percent in the stent-plus-abciximab group (hazard ratio, 0.82; 95 percent confidence interval, 0.59 to 1.13; P=0.22) and 15.4 percent in the angioplasty-plus-abciximab group (hazard ratio, 1.49; 95 percent confidence interval, 1.13 to 1.97; P=0.005). The hazard ratio for stenting plus abciximab as compared with angioplasty plus abciximab was 0.55 (95 percent confidence interval, 0.41 to 0.74; P<0.001). Among patients with diabetes, the combination of abciximab and stenting was associated with a lower rate of repeated target-vessel revascularization (8.1 percent) than was stenting and placebo (16.6 percent, P=0.02) or angioplasty and abciximab (18.4 percent, P=0.008). For coronary revascularization, abciximab and stent implantation confer complementary long-term clinical benefits.
Medical subject headings
- Angioplasty, Balloon, Coronary
- Antibodies, Monoclonal
- Coronary Disease
- Immunoglobulin Fab Fragments
- Platelet Aggregation Inhibitors
- Platelet Glycoprotein GPIIb-IIIa Complex
- Stents