Effect of the laryngeal mask airway on oesophageal pH: influence of the volume and pressure inside the cuff.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 10472224.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We studied gastro-oesophageal reflux (GOR) with a face mask and laryngeal mask airway (LMA), and the effects of inflation pressure and volume of the LMA cuff on oesophageal pH, in 60 patients. Patients were managed with either a face mask (group I) or LMA inflated to obtain a seal in the anaesthesia circuit at 7 cm H2O (group II) or 15 cm H2O (group III). A pH-sensitive probe with two electrodes, 10 cm apart, was placed in the oesophagus during anaesthesia and recordings were made continuously until patients awakened. There was a significant difference in the incidence of GOR between the face mask (group I) and the LMA (groups II-III) (P < 0.05) in the lower oesophagus but there was no difference in the mid-oesophagus. No correlation was found between pressure and volume inside the cuff and variations in oesophageal pH. We conclude that LMA use was associated with increased reflux in the low oesophagus but oesophageal pH was not influenced by variations in pressure or volume inside the LMA cuff.
Medical subject headings
- Gastroesophageal Reflux
- Laryngeal Masks