White matter lesion contrast in fast spin-echo fluid-attenuated inversion recovery imaging: effect of varying effective echo time and echo train length.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 10511185.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Our aim was to determine whether the contrast between white matter lesions and normal-appearing white matter in fast spin-echo fluid-attenuated inversion recovery (FLAIR) images can be improved by lengthening the effective TE and the echo train length. Thirty patients with various white matter lesions were imaged using fast spin-echo FLAIR sequences (TR = 10,002 msec; inversion time = 2200) on a 1.5-T MR imaging system. For 14 patients, fast spin-echo FLAIR sequences with a TE of 165 msec and echo train length of 32 (fast spin-echo FLAIR 165/32) were compared with fast spin-echo FLAIR sequences with a TE of 125 msec and echo train length of 24 (fast spin-echo FLAIR 125/24). For 16 other patients, fast spin-echo FLAIR 165/32 sequences were compared with fast spin-echo FLAIR sequences with a TE of 145 msec and echo train length of 28 (fast spin-echo FLAIR 145/28). Signal difference-to-noise ratios were calculated between the lesions and normal-appearing white matter for a typical lesion in each patient. In both groups, a small but statistically significant increase in the signal difference-to-noise ratio was found on the fast spin-echo FLAIR sequences using the longer TE and echo train length. In the first group, signal difference-to-noise ratio increased from 18.7 +/- 4.7 (mean +/- SD) for fast spin-echo FLAIR 125/24 to 20.1 +/- 4.5 for fast spin-echo FLAIR 165/32 (p < .05). In the second group, the signal difference-to-noise ratio increased from 15.4 +/- 4.0 for fast spin-echo FLAIR 145/28 to 16.8 +/- 4.6 for fast spin-echo FLAIR 165/32 (p <.01). In addition, fast spin-echo FLAIR sequences with a longer TE and echo train length were obtained more rapidly (6 min for fast spin-echo FLAIR 125/24, 5 min 20 sec for fast spin-echo FLAIR 145/28, and 4 min 41 sec for fast spin-echo FLAIR 165/32). Lengthening the TE to 165 msec and echo train length to 32 in fast spin-echo FLAIR imaging allows both a mild improvement in the contrast between white matter lesions and normal-appearing white matter and shorter imaging times.
Medical subject headings
- Brain
- Brain Diseases
- Magnetic Resonance Imaging