Abstract
The wavelet transform technique, a time-frequency method with logarithmic frequency resolution, was used to analyze oscillations in human peripheral blood flow measured by laser Doppler flowmetry. The oscillations extended over a wide frequency scale and their periods varied in time. Within the frequency range studied, 0.0095-1.6 Hz, five characteristic oscillations were revealed, arising from both local and central regulatory mechanisms. After the insertion of endothelium-dependent and endothelium-independent vasodilators the spectra of blood flow markedly differed in the frequency interval 0.0095-0.02 Hz. In this way it was demonstrated that endothelial activity is a rhythmic process that contributes to oscillations in blood flow with a characteristic frequency of around 0.01 Hz. The study illustrates the potential of laser Doppler flowmetry combined with dynamical systems analysis for studies of both the micro- and macroscopic mechanisms of blood flow regulation in vivo.
Medical subject headings
- Laser-Doppler Flowmetry
- Signal Processing, Computer-Assisted
- Skin