Late aneurysm formation in a femoro-popliteal polytetrafluoroethylene graft.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 10525890.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Since improvement in the material, true aneurysms and pseudoaneurysm formations have become relatively rare complications after femoro-popliteal reconstruction with polytetrafluoroethylene (PTFE) grafts. We report a case of late graft rupture and pseudoaneurysm formation within the straight femoral part of a femoro-popliteal bypass with reinforced (PTFE-wrapped) Gore-Tex graft. The rupture occurred 7 years after implantation without history of direct traumatization. Intraoperatively the whole bypass showed macro- and microscopically visible deterioration of the wall with almost complete disruption at the site of the aneurysm. The graft had to be replaced completely. In conclusion, we recommend continuous long-term follow-up of these patients preferably with duplex ultrasonography.
Medical subject headings
- Aneurysm, False
- Blood Vessel Prosthesis
- Femoral Artery
- Popliteal Artery