The Ranawat Award. Femoral component rotation during total knee arthroplasty.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 10546596.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
One-hundred consecutive posterior cruciate retaining total knee arthroplasties were performed by one surgeon in 81 patients with an average age of 69 years. Diagnoses included osteoarthritis in 93 knees and rheumatoid arthritis in seven. The femoral alignment necessary to create a rectangular flexion gap was determined and compared with Whiteside's line, the transepicondylar axis, and a line in 3 degrees external rotation relative to the posterior condyles of the femur. The transepicondylar axis most consistently recreated a balanced flexion space whereas 3 degrees external rotation off the posterior condyles was least consistent especially in knees in valgus.
Medical subject headings
- Arthroplasty, Replacement, Knee
Anatomy
- femur
- knee