Emergency correction of coagulation for mitral valve replacement in an orally anticoagulated 17-year-old patient with pronounced hepatic dysfunction.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 10551970.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A 17-year-old patient with Shone's disease had to be readmitted to the hospital 3 months after implantation of an artificial aortic valve because of extreme mitral insufficiency with consecutive pulmonary edema and hepatic dysfunction. He had been orally anticoagulated and presented with a high international normalized ratio of 6.7. Emergency replacement of the mitral valve was possible only after administration of prothrombin-complex concentrate, as vitamin K(1) and fresh frozen plasma did not correct the hemostatic defect sufficiently.
Medical subject headings
- Aortic Valve Stenosis
- Coagulation Protein Disorders
- Heart Failure
- Heart Valve Prosthesis Implantation
- Liver Diseases
- Mitral Valve Insufficiency
- Mitral Valve Stenosis
- Pulmonary Edema
- Ventricular Outflow Obstruction