Compression arthrodesis of the ankle by triangular external fixation: biomechanical and clinical evaluation.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 10604806.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This article describes a technique of ankle arthrodesis using a triangular external fixation frame and presents the results of biomechanical analysis and clinical experience with the frame. Clinical evaluation of 23 ankle arthrodeses performed using a triangular external fixation frame yielded a 91.3% fusion rate at an average of 11 weeks postfusion. The triangular frame was 79% stiffer than a compression-only external frame in torsion and 39% stiffer in anteroposterior bending. This high rate of fusion is attributed to the elimination of micromotion at the fusion site because of the increased rigidity of the triangular external compression frame.
Medical subject headings
- Ankle Injuries
- Arthrodesis
- External Fixators
Anatomy
- ankle