The cylindrical titanium mesh cage for treatment of a long bone segmental defect: description of a new technique and report of two cases.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 10630804.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This report describes a new technique for treatment of a segmental defect in long bones that uses a cylindrical titanium mesh cage, in combination with cancellous bone allograft and demineralized bone matrix putty (Grafton), stabilized with a statically locked intramedullary nail. Two clinical cases of tibia defects treated with this technique are presented. At the one-year follow-up, radiographically both cases demonstrated excellent limb alignment, stability, and bony healing. Immediate full weight-bearing was initiated in each case, and early limb functional recovery was achieved. Preliminary data suggest that this technique may be a reasonable alternative to currently used methods for management of select long bone segmental defects.
Medical subject headings
- Surgical Mesh
- Tibia
- Titanium
Anatomy
- tibia