Standardized probe-directed sentinel node dissection in melanoma.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 10660755.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Radiopharmaceutical agents appear to improve the accuracy of sentinel node (SN) identification in patients with early-stage melanoma, but the optimal radiopharmaceutical agent and its timing from injection to surgery remain controversial. We undertook this investigation to examine the utility of 3 methods of intraoperative lymphatic mapping with radiopharmaceutical-directed sentinel lymphadenectomy (LM/SL). We suspected that concurrent injection of radiopharmaceutical and blue-dye would lead to the greatest success of SN identification. The study was composed of 247 consecutive patients who had American Joint Committee on Cancer stage I or II melanoma. Before LM/SL, all patients underwent cutaneous lymphoscintigraphy by 1 of 3 techniques: technetium 99m (Tc 99m) human serum albumin (HSA) injected at least 24 hours before LM/SL (124 patients), Tc 99m filtered sulfur colloid (SC) injected no more than 4 hours before LM/SL (same-day SC, 95 patients), or Tc 99m SC injected at least 18 hours before LM/SL (prior-day SC, 28 patients). At the time of LM/SL, isosulfan blue dye was injected alone (SC groups) or with a second dose of HSA (HSA group). A hand-held gamma probe was used to determine the radioactive (hot) counts of blue-stained and nonstained nodes, and the in vivo and ex vivo node-to-background count ratios of the nodes were compared. Preoperative LS identified 299 drainage basins; LM/SL identified at least 1 SN in 119 (98%) of 121 basins using same-day SC, 142 (97%) of 146 basins using HSA, and 32 (100%) of 32 basins using prior-day SC. There was no difference (P = .62) in the accuracy rate between the 3 techniques. The total number of SNs was 463. Same-day SC yielded higher intraoperative node-to-background count ratios than did either of the other techniques (P < .0001). Same-day SC also had the greatest relative change in radioactivity between the blue sentinel node and the post-excision basin (P < .0001), and the highest rate of SNs that were both blue and hot (in vivo or ex vivo ratio > or = 2, P = .05). LS and LM/SL performed on the same day with a single injection of filtered Tc 99m SC serves as the most useful method for probe-directed LM/SL. This technique demonstrated the highest in vivo and ex vivo count ratios, fall-off of radioactivity between the excised nodes and post-excision basin, and concordance between blue dye and hot nodes. It should be recommended as the method of choice for probe-directed LM/SL.
Medical subject headings
- Lymph Node Excision
- Melanoma
- Sentinel Surveillance