Procedural results and late clinical outcomes after percutaneous interventions using long (> or = 25 mm) versus short (< 20 mm) stents.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 10716462.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To evaluate clinical outcomes after the use of long coronary stents. The use of long slotted-tube stents has been recently approved in the U.S. to treat long lesions or dissections. Procedural success and long-term outcomes of long versus short stents have not been established. We evaluated procedural success, major in-hospital complications, target lesion revascularization and long-term (one year) clinical outcomes in 1,226 consecutive patients (1,259 native coronary lesions) who underwent a single vessel intervention using a single long (> or =25 mm, 116 patients) or short (<20 mm, 1,110 patients) tubular-slotted stent. Patients treated with long stents had more diffuse (>10 mm length) lesions (63% vs. 28%, p = 0.001). The mean stent length was 28 +/- 5 mm versus 15 +/- 2 mm for long versus short stent groups (p = 0.001). Overall procedural success was similar in the long versus short stent groups (96% vs. 98%, p = 0.08). However, major in-hospital complications tended to occur more frequently in patients treated with longer stents (3.4% vs. 1.0%, p = 0.04). The rate of periprocedural non-Q-wave myocardial infarction (MI) (creatine kinase-MB > or =5 times normal) was notably higher after long stent implantation (23% vs. 11%, p = 0.001). Target lesion revascularization at one year was 14.5% vs. 13.8% (p = 0.69), and target vessel revascularization rate was 19.6% vs. 17.3% (p = 0.41) in the long versus short stent group, respectively. There was no difference in one year mortality (2.5% vs. 3.5%, p = 0.49) or Q-wave MI (2.7% vs. 1.2%, p = 0.48), and the overall cardiac event-free survival was similar for the two groups (81%). The use of single coronary long (> or =25 mm) versus short (<20 mm) stents is associated with: 1) somewhat increased major procedural complications, 2) significantly higher frequency of periprocedural non-Q-wave MIs, and 3) equivalent repeat revascularization risk and cardiac event-free survival out-of-hospital up to one year.
Medical subject headings
- Blood Vessel Prosthesis Implantation
- Coronary Disease
- Myocardial Revascularization
- Stents