Effects of pulsed magnetic energy on a microsurgically transferred vessel.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 10744227.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This article reports the findings of a study that attempted to elucidate whether pulsed magnetic energy stimulates neovascularization in vivo, using a microsurgically created arterial loop model in a prospective randomized trial of 108 rats (n = 12/group). Pulsed magnetic energies of 0.1 and 2.0 gauss were applied immediately postoperatively and for 4, 8, and 12 weeks, respectively, with a statistically significant increase in neovascularization among the treated animals compared with control rats. The study provides a starting point for future study and evaluation of the stimulation of angiogenesis with the use of pulsed magnetic energy and suggests a possible use of this modality to increase the quality of revascularized tissue.
Medical subject headings
- Electromagnetic Fields
- Neovascularization, Physiologic
- Surgical Flaps