Position-dependent ventricular tachycardia related to a peripherally inserted central catheter.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 10761499.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Recently, peripherally inserted central venous catheters (PICCs) have been widely used for venous access. Advantages of a PICC over centrally inserted central catheters include the virtual elimination of the risk of pneumothorax, hemothorax, and arterial puncture, along with a reduced risk of bleeding. However, the PICC has associated risks. We present 2 cases of body position-dependent ventricular tachycardia related to PICCs. These events occurred in patients with no prior history of cardiac arrhythmia and were corrected by repositioning of the PICC. They serve to identify a potentially serious cardiac complication of the PICC that, to our knowledge, has not been described previously.
Medical subject headings
- Catheterization, Central Venous
- Tachycardia, Ventricular