Diagnostic failures in endoscopy for acute upper gastrointestinal haemorrhage.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 10792319.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Oesophagogastroduodenoscopy (OGD) is the diagnostic tool of choice in acute upper gastrointestinal haemorrhage. However, the factors causing diagnostic failure are not well documented or discussed. OGDs performed by a single surgeon for acute upper gastrointestinal haemorrhage were reviewed retrospectively for 'missed' diagnosis. There were nine cases (1.4 per cent) of 'missed' diagnosis in 638 OGDs performed over a 3-year period. Incomplete examination caused by a fundal pool precluded three examinations in which two Dieulafoy's lesions and one chronic gastric ulcer were later found. Other difficult examination sites were the cardia/high lesser curve (three cases), the stomal line of a gastrojejunostomy anastomosis (two) and at the junction of the first and second part of the duodenum (one). Four of the overlooked diagnoses were Dieulafoy's lesions. OGD was able to diagnose the cause of bleeding in 98.6 per cent of patients with acute upper gastrointestinal haemorrhage. The factors that caused diagnostic failure were a difficult examination site and failure to recognize lesions (Dieulafoy's).
Medical subject headings
- Endoscopy, Gastrointestinal
- Gastrointestinal Hemorrhage