An intra-articular bioabsorbable interference screw mimicking an acute meniscal tear 8 months after an anterior cruciate ligament reconstruction.

Bottoni, C R; Deberardino, T M; Fester, E W; Mitchell, D; Penrod, B J · Arthroscopy · 2000

case_report · Level V

Where this comes from

Abstract

Seven months after a quadrupled semitendinosus anterior cruciate ligament reconstruction, a 44-year-old active-duty soldier reported symptoms consistent with a medial meniscus tear. Preoperative magnetic resonance imaging showed an intra-articular bioabsorbable interference screw within his intercondylar notch. The screw was retrieved arthroscopically. The graft was intact and functional except for a small portion of the anterior fibers, which were debrided. The patient returned to full activities without complaints.

Medical subject headings

Anatomy