Spontaneous variability of cardiac output in ventilated critically ill patients.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 10809263.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To define the magnitude of spontaneous cardiac output variability over time in sedated medical intensive care unit patients attached to a continuous cardiac output monitor, and to determine whether high level positive end-expiratory pressure or inverse inspiratory-to-expiratory (I:E) ratio ventilation resulted in greater variability over time than low positive end-expiratory pressure with conventional I:E ratio ventilation. Prospective study. Medical intensive care unit in a tertiary medical center. A total of 22 hemodynamically stable acute respiratory failure patients with a pulmonary artery catheter inserted for hemodynamic monitoring After being sedated, patients were randomized ultimately to receive pressure control ventilation first at setting A (high positive end-expiratory pressure [15 cm H2O] with conventional I:E ratio [1:2]) and then at setting B (low positive end-expiratory pressure [5 cm H2O] with inverse I:E ratio [2:1]), or vice versa, and then at setting C (low positive end-expiratory pressure [5 cm H2O] with conventional I:E ratio [1:2]). Each ventilation setting period lasted 1 hr. Cardiac output (CO) was measured continuously. The continuous CO value displayed was updated every 30-60 secs. The updated value reflected an average of the previous 3-6 mins. The coefficient of variation (CV) of CO for each setting in each patient was calculated to represent the spontaneous variability. The mean CO+/-SD and CV of each setting was 5.7+/-1.8 L/min and 4.4% for setting A, 5.6+/-1.5 L/min and 4.6% for setting B, and 5.9+/-1.7 L/min and 4.8% for setting C. Analysis of variance revealed no significant differences between the CVs of the three settings. The 95% confidence interval for the COs for each setting was approximately the mean CO+/-0.1 x mean CO measured. In critically ill sedated medical intensive care unit patients with stable hemodynamics, the spontaneous variability of cardiac output over time was not significant. High positive end-expiratory pressure (15 cm H2O) and inverse ratio ventilation (2:1) did not contribute to increased spontaneous variability of cardiac output.
Medical subject headings
- Cardiac Output
- Critical Illness
- Respiration, Artificial