CT-guided percutaneous fibrin glue therapy of cerebrospinal fluid leaks in the spine after surgery.

Patel, M R; Caruso, P A; Yousuf, N; Rachlin, J · AJR Am J Roentgenol · 2000

case_series · Level IV

Where this comes from

Abstract

The objective of this study is to assess CT-guided percutaneous injection of fibrin glue for the management of cerebrospinal fluid leaks within the spine. Percutaneous CT-guided placement of fibrin glue can provide a treatment option for postoperative cerebrospinal fluid leaks, potentially allowing a major surgical procedure to be avoided. However, the complication of aseptic meningitis may occasionally result from this procedure.