Transcaruncular approach to the medial orbit and orbital apex.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 10919889.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To present a versatile approach to the medial orbit and orbital apex through the caruncle. Retrospective, noncomparative, case series with description of surgical technique. Twenty-five consecutive patients underwent orbital surgery by use of a transcaruncular approach. Inferior and medial wall fracture repair or orbital decompression by means of a transcaruncular or combined transfornix-transcaruncular approach. The surgical indications and complications were recorded for each patient. Ten patients (10 orbits) underwent combined inferior and medial orbital wall fracture repair through a combined transfornix-transcaruncular approach. In 8 of 10 (80%) orbits, the inferior oblique muscle was disinserted during surgery. Fifteen patients (24 orbits) underwent orbital decompression surgery for dysthyroid orbitopathy. An isolated transcaruncular approach was used in 5 of 24 orbits, and a combined transfornix-transcaruncular approach was used in 19 of 24 orbits. There were no complications related to either approach. Orbital bone removal and fracture reduction may be safely completed through a combined transfornix-transcaruncular approach. The transcaruncular approach provides excellent and safe exposure of the medial orbital wall, and it avoids scarring associated with the Lynch approach.
Medical subject headings
- Ophthalmologic Surgical Procedures
- Orbit
- Orbital Diseases