Absolute renal blood flow quantification by dynamic MRI and Gd-DTPA.

Vallée, J P; Lazeyras, F; Khan, H G; Terrier, F · Eur Radiol · 2000

other

Where this comes from

Abstract

The aim of this study was to demonstrate the feasibility of the absolute renal blood flow quantification using MRI and injection of contrast media. Using a T1-weighted fast gradient sequence following an intravenous bolus injection of Gd-DTPA, dynamic images of the kidney were obtained in patients with well-functioning native kidneys (n = 7) or transplant (n = 9), with significant renal artery stenosis (n = 4) and with renal failure (n = 7). After signal intensity calibration, the absolute renal perfusion was equal to the wash-in slope of the renal transit curve divided by the contrast medium concentration at the peak of the bolus in the aorta. The cortical blood flow was 2.54+/-1.16 ml/min per gram in well-functioning kidneys decreasing to 1.09+/-0.75 ml/min per gram in case of renal artery stenosis (p = 0.04) and to 0.51+/-0.34 ml/min per gram in case of renal failure (P<0.001). These measurements were in agreement with previous results obtained by other methods. A standard MRI imaging sequence and a simple model can provide realistic quantitative data on renal perfusion. This work justifies further studies to compare this model with a gold standard for renal blood flow measurements.