Evaluating mechanical adhesion of sol-gel titanium dioxide coatings containing calcium phosphate for metal implant application.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 10985493.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The adhesion of thin (< 10 microm) sol-gel calcium phosphate-titanium dioxide films bonded to a titanium substrate was studied using two different tests: a rotating-bending test and a tensile bond test. The former evaluates the impact of both the coating procedure and the surface pre-treatment on the resistance to fatigue of the substrate as well as the adhesion of the coating; the latter measures the tensile adhesion strength of the coating. Both tests gave similar results. A reduction of the thickness of the coating or an increase of the roughness of the substrate improves the quality of the interface. A comparison of the adhesion of the calcium phosphate-titanium dioxide film with that of a pure calcium phosphate coating obtained by a similar route suggests the involvement of a chemical component in the binding.
Medical subject headings
- Calcium Phosphates
- Coated Materials, Biocompatible
- Prostheses and Implants
- Titanium