Median nerve compression by a radially inserted palmaris longus tendon after release of the antebrachial fascia: A complication of carpal tunnel release.

Nakamichi, K; Tachibana, S · J Hand Surg Am · 2000

case_report · Level V

Where this comes from

Abstract

We describe a case that had recurrent median nerve compression after release of the antebrachial fascia in carpal tunnel release. The nerve was compressed by a palmaris longus tendon that was inserted radially into the thenar fascia. After decompression (detachment of the tendon) the patient had symptom relief. Release of the antebrachial fascia in the presence of this tendon variant carries a risk of median nerve compression by the tendon.

Medical subject headings