Monitoring of motor and somatosensory evoked potentials provides instantaneous intraoperative assessment of a patient's neurologic status. Monitoring of the sciatic nerve through motor and somatosensory evoked potentials can be used during open reduction and internal fixation of pelvic and acetabular fractures. A review of 12 pelvic and acetabular fractures treated with open reduction and internal fixation was conducted and assessed with a combination of intraoperative motor and somatosensory evoked potential monitoring. Results revealed intraoperative motor evoked potential monitoring was 100% sensitive and 100% specific in predicting postoperative sciatic nerve deficits, whereas somatosensory evoked potentials were not accurate in predicting postoperative sciatic nerve deficits. Combined monitoring of the sciatic nerve with motor and somatosensory evoked potentials is beneficial at predicting postoperative sciatic nerve deficits during open reduction and internal fixation of pelvic and acetabular fractures.