Acetabular reconstruction with impacted morcellized cancellous bone autograft and cemented primary total hip arthroplasty: a 10- to 17-year follow-up study.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 11061440.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
During the period 1979 through 1986, 69 acetabular reconstructions in 63 patients were performed with the use of autologous morcellized bone-grafts because of acetabular bone stock loss. Nine cases (10 hips) were lost to follow-up. Eleven patients (12 hips) died <10 years after surgery; none had a revision. The results for the remaining 43 patients (47 hips) were reviewed at an average interval of 12.3 years (range, 10-17 years). No preoperative Harris hip score was available. The average Harris hip score at follow-up was 88 (range, 60-100). Radiographically, all grafts united. One hip developed a deep infection. Three other hips (6%) were revised because of aseptic loosening of the acetabular component. An additional 3 acetabular components were considered radiographic failures. Excluding the infected case, the overall survival rate of these acetabular reconstructions with a revision as endpoint was 94% at an average follow-up of 12.3 years. Reconstruction of acetabular bone stock loss with autologous morcellized bone-grafts is an attractive technique with a good potential for long-term success.
Medical subject headings
- Acetabulum
- Arthroplasty, Replacement, Hip
- Bone Transplantation
Anatomy
- hip
- pelvis