Diagnosis and management of left ventricular assist device valve-endocarditis: LVAD valve replacement.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 11081912.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A 57-year-old man who has been wearing a Novacor N100 left ventricular assist device (LVAD) for more than 3 years suffered from LVAD endocarditis. Only by immunoscintigraphic methods was it possible to localize the septic focus. After successful exchange of in- and outflow tract valves, the infection was eradicated. Microscopic investigation confirmed the scintigraphic findings: Gram-positive bacteria were found. The valves showed no gross degenerative lesions after more than 1,100 days of implantation. The patient is now doing well.