Hearing loss after spinal and general anesthesia: A comparative study.

Schaffartzik, W; Hirsch, J; Frickmann, F; Kuhly, P; Ernst, A · Anesth Analg · 2000

Level II

Where this comes from

Abstract

Hearing loss has been described after spinal anesthesia. We examined the hearing in patients before and after spinal and general anesthesia by pure tone audiometry (LdB: 125-1500 Hz; HdB: 2000-8000 Hz). Tympanic membrane displacement analysis was used to noninvasively monitor the intralabyrinthine and intracranial pressure. Eighteen patients received spinal anesthesia (G(SA)); 19 patients general anesthesia (G(GA)). Pure tone audiometry and TMD data were obtained preoperatively ((0)) and postoperatively on day 1 ((1)) and 2 ((2)). The mean threshold differences (Delta) in LdB(10) and LdB(20) were significantly different in G(SA) compared with G(GA) (DeltaLdB(10) + 0.15+/-3.07 dB vs. -1.34+/-3.77 dB, P = 0.05; DeltaLdB(20) -0.54+/-2.24 dB vs. -2.45+/-3.39 dB, P<0.01). However, there were no differences in DeltaHdB(10) between G(SA) and G(GA), but in DeltaHdB(20) (-1.40+/-3.95 dB vs -5.12+/- 6.35 dB, P = <0.01). We found a significant correlation between the magnitude of intraoperative intravascular volume replacement and low-frequency hearing loss. Tympanic membrane displacement values were not different pre- and postoperatively. Hearing was impaired after spinal and general anesthesia. Low-frequency hearing loss was correlated with intraoperative volume replacement. Tympanic membrane recordings did not reveal significant changes.