Somatosensory evoked potentials for closed-loop control of anaesthetic depth using propofol in the urethane-anaesthetized rat.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 11103186.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Primary somatosensory cortical mass responses have been shown to exhibit dose-dependent changes in latency when general anaesthetics are administered. Here we describe a system in which the latency of evoked responses was measured automatically in real time in five animals. Latency changes were used to operate a closed-loop control of propofol delivery by intravenous infusion. The system attempted to induce and maintain a 1 ms increase in evoked response latency; this was reversed when infusion was discontinued. Allowing for the rapid and large biological fluctuations in the evoked response, this was achieved successfully. The system maintained a mean increase in latency of 1.27 (SD 0.42) ms. The mean statistical dispersion index of data obtained during the controlled period was 1.23 (0.3); in an ideal controllable system it approximates to 1. Such a system may provide a means for the automatic delivery of anaesthetics.
Medical subject headings
- Anesthesia, Closed-Circuit
- Anesthesia, Intravenous
- Anesthetics, Intravenous
- Evoked Potentials, Somatosensory
- Propofol
- Reaction Time