Multiple telescoping anastomosis on an artery.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 11119289.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The telescoping anastomotic technique was carried out four times on the rat femoral artery in order to examine whether the technique could safely be used three to four times for repair of an artery that was injured at two different sites. In addition, the technique was repeated five and six times to determine the maximum number of anastomosis that could be performed on an artery and to clarify problems of the telescoping anastomosis. In the rats in which the anastomosis was carried out four and five times, 100% patency was obtained, while the first occlusion occurred in a graft on which the anastomosis was repeated six times. The telescoping technique appeared to safely be used three or four times for repair of an artery that had been divided at two sites if tension of the repaired vessel was kept low by the grafting, and torsion of the graft and deformities of the inserted vessel were minimal.
Medical subject headings
- Arteriovenous Shunt, Surgical