Modified technique of haptic externalization for scleral fixation of dislocated posterior chamber lens implants.

Kokame, G T; Atebara, N H; Bennett, M D · Am J Ophthalmol · 2001

case_report · Level V

Where this comes from

Abstract

To describe a modified technique of haptic externalization during repositioning of dislocated posterior chamber lens implants, which facilitates placement of scleral fixation sutures around the haptic for implant stabilization. We describe a technique of repositioning a dislocated posterior chamber implant with scleral fixation sutures, which uses a small, clear corneal incision for externalization of the haptic. After a loop of 10-0 Prolene suture (Ethicon, Inc., Somerville, New Jersey) is placed around the externalized haptic, the sutures are retrieved through a sclerotomy 1.0 mm posterior to the limbus. The haptic is reimplanted into the ciliary sulcus. A separate scleral fixation bite closes the sclerotomy, and it is tied to the 10-0 Prolene sutures looped around the haptic. The dislocated implant was stable and fixated in good position 5 months after surgery using this technique. This externalization technique minimizes the extensive intraocular manipulations necessary to create a suture loop around a haptic of a dislocated implant. The clear corneal incision allows for clear visualization during externalization of the haptic.

Medical subject headings