Energy system contribution during 200- to 1500-m running in highly trained athletes.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 11194103.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of the present study was to profile the aerobic and anaerobic energy system contribution during high-speed treadmill exercise that simulated 200-, 400-, 800-, and 1500-m track running events. Twenty highly trained athletes (Australian National Standard) participated in the study, specializing in either the 200-m (N = 3), 400-m (N = 6), 800-m (N = 5), or 1500-m (N = 6) event (mean VO2 peak [mL x kg(-1)-min(-1)] +/- SD = 56+/-2, 59+/-1, 67+/-1, and 72+/-2, respectively). The relative aerobic and anaerobic energy system contribution was calculated using the accumulated oxygen deficit (AOD) method. The relative contribution of the aerobic energy system to the 200-, 400-, 800-, and 1500-m events was 29+/-4, 43+/-1, 66+/-2, and 84+/-1%+/-SD, respectively. The size of the AOD increased with event duration during the 200-, 400-, and 800-m events (30.4+/-2.3, 41.3+/-1.0, and 48.1+/-4.5 mL x kg(-1), respectively), but no further increase was seen in the 1500-m event (47.1+/-3.8 mL x kg(-1)). The crossover to predominantly aerobic energy system supply occurred between 15 and 30 s for the 400-, 800-, and 1500-m events. These results suggest that the relative contribution of the aerobic energy system during track running events is considerable and greater than traditionally thought.
Medical subject headings
- Energy Metabolism
- Running