Delayed effects of a migrated foreign body (sewing needle) in the cervical spine: a case report.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 11242388.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A case report is presented. This report documents one case of intraspinal migration of a metal foreign body. The migration and penetration of foreign bodies into the spine have been described, but there are only three reports of a needle as the causative object. This case report included a chart review, an examination of the patient, and a literature search. The patient successfully underwent surgery, in which the foreign body (a sewing needle) was removed. It is important to be aware of the possible delayed penetration of a foreign body into the spine even in patients with few or no symptoms.
Medical subject headings
- Cervical Vertebrae
- Foreign-Body Migration
- Needles
- Spinal Cord Injuries
- Spinal Injuries
Anatomy
- cervical spine