What is the relationship between paresthesia and nerve stimulation for axillary brachial plexus block?
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 11251131.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To quantify the motor threshold current of a needle following elicitation of paresthesia during axillary brachial plexus block (ABPB). This is a prospective, observational study of ABPB in 72 patients. Having elicited paresthesia, the minimum current required to produce a motor response was noted. The development and success of the block were subsequently followed. Nineteen blocks were excluded (18 because of arterial puncture and 1 blocked needle). Of the remaining 53 blocks, 41 (77%) produced a motor response at 0.5 mA or less. The median current was 0.17 mA (range, 0.03 to 3.3 mA). The site of initial paresthesia and subsequent motor response were related in 43 (81%) of cases. A needle position causing paresthesia produced a motor response at 0.5 mA or less in 77% of cases studied. This current may, therefore, be a reasonable threshold to aim for when performing an ABPB.
Medical subject headings
- Axilla
- Brachial Plexus
- Nerve Block
- Paresthesia