Management of massive postpartum haemorrhage: use of a hydrostatic balloon catheter to avoid laparotomy.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 11305551.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Postpartum haemorrhage remains a significant complication of childbirth in the UK and worldwide. The most common cause of postpartum haemorrhage is uterine atony, but placent accreta is becoming more frequent. In these situations tamponade may be required. The successful use of the inflated stomach balloon (300ml) of a Sengstaken-Blakemore tube has been reported previously. We describe an innovative method of 'tamponade' which is simple and effective, using the Rüsch urological hydrostatic balloon catheter. In two cases of failed medical therapy for PPH, where the catheter has been tried, further surgical interventions have been avoided.
Medical subject headings
- Balloon Occlusion
- Catheterization
- Postpartum Hemorrhage