Catheter ablation of a monofocal premature ventricular complex triggering idiopathic ventricular fibrillation.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 11410580.
- Also identified by PMC identifier 1729809.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A 62 year old man was admitted for evaluation of recurrent episodes of syncope. A surface ECG showed frequent repetitive premature ventricular complexes of right ventricular outflow tract origin. Ventricular fibrillation was inducible by programmed electrical stimulation but otherwise cardiac evaluation was unremarkable. A diagnosis of idiopathic ventricular fibrillation was made and an implantable cardioverter-defibrillator (ICD) was installed. However, spontaneous ventricular fibrillation recurred, requiring repeated ICD discharges. The ventricular fibrillation was reproducibly triggered by a single premature ventricular complex with a specific QRS morphology. Radiofrequency catheter ablation was carried out to eradicate this complex. No ventricular fibrillation has developed after this procedure, and the patient does not require drug treatment.
Medical subject headings
- Catheter Ablation
- Ventricular Fibrillation