99mTc-HMPAO leucocyte scintigraphy fails to detect Crohn's disease in the proximal gastrointestinal tract.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 11420197.
- Also identified by PMC identifier 1718846.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To investigate the use of (99m)Tc-HMPAO (hexamethyl propylene amine oxime) leucocyte scintigraphy as a non-invasive screening test for inflammatory bowel disease. 10 children with suspected Crohn's disease, in whom routine investigation using barium contrast radiology, upper gastrointestinal endoscopy, colonoscopy, and mucosal biopsies had identified severe gastroduodenal and/or jejunal involvement. (99m)Tc-HMPAO leucocyte scintigraphic studies performed in each of these cases were assessed by a radiologist who was blinded to the disease distribution. In nine cases there was no scintigraphic evidence of inflammation in the proximal gastrointestinal tract. The 10th child had both gastroduodenal and jejunal involvement, but scintigraphy only revealed faint jejunal positivity. (99m)Tc-HMPAO leucocyte scintigraphy should not be depended upon as a screening test for Crohn's disease. False negative results are likely in cases with Crohn's disease confined to the proximal gastrointestinal tract.
Medical subject headings
- Crohn Disease
- Gastritis
- Radiopharmaceuticals
- Technetium Tc 99m Exametazime