An unusual case of bioprosthetic mitral valve thrombosis.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 11465193.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Bioprosthetic valve thrombosis and related embolism are considered extremely unlikely, thus allowing most patients to avoid long-term anticoagulation. There is, however, limited experience in the diagnosis and treatment of such a condition. We present the case of a patient with a porcine mitral bioprosthesis who presented with acute thrombosis with unusual echocardiographic features. A favorable outcome was observed after conventional anticoagulant treatment.
Medical subject headings
- Bioprosthesis
- Heart Valve Prosthesis
- Heparin
- Mitral Valve Insufficiency
- Postoperative Complications
- Thrombosis