Implantable cardioverter defibrillator patch erosion in a heart transplant patient.

Chilukuri, S; Herlihy, J P; Massumkhani, G A; Duncan, J M; Frazier, O H · Ann Thorac Surg · 2001

case_report · Level V

Where this comes from

Abstract

A 57-year-old man who had received an automatic implantable cardioverter defibrillator and subsequent orthotopic heart transplant presented to medical attention for hemoptysis. The hemoptysis was caused by the migration of the left ventricular patch of the automatic implantable cardioverter defibrillator, which had been left in place at the time of orthotopic heart transplant. The patch had eroded into the left lung. We recommend that implantable cardioverter defibrillators be removed completely at the time of heart transplantation to prevent subsequent complications.