Aortic dissection: percutaneous management with a separating stent-graft--preliminary results.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 11477265.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The authors used a separating stent-graft to treat Stanford type B aortic dissection. The separating stent-graft consists of two stents: a stent-graft and an inner bare stent. The separating stent-graft has three parts: a proximal stent, a graft made of synthetic polyester textile fiber, and a distal stent. A 12-F introducing sheath was used. After the separating stent-graft was placed, false-lumen thrombosis was evident in all six patients during a follow-up period of 206 days. The major advantages of this technique are that a cutdown and blood pressure control are not required.
Medical subject headings
- Aortic Dissection
- Aortic Aneurysm
- Blood Vessel Prosthesis
- Stents