Pulmonary sequelae after electron spinal irradiation.

Endicott, T J; Fisher, B J; Wong, E; Paterson, N A; Gaspar, L E; Bauman, M · Radiother Oncol · 2001

case_series · Level IV

Where this comes from

Abstract

We measured pulmonary function in 21 patients, after craniospinal irradiation with a posterior spinal electron beam. The median age at treatment was 7.5 years. Nine patients (43%) demonstrated abnormal pulmonary function tests, five with restrictive changes, one with isolated diminished diffusion capacity, and three with obstructive disease. These changes were mild and predominantly asymptomatic.