Direct closure of ostium primum defect in the repair of atrioventricular septal defect.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 11515878.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Patch closure is generally performed for atrial septation of an atrioventricular septal defect. We recently developed a new surgical technique for repairing atrioventricular septal defects that avoids the use of any patch material for closing the atrial septal defect. We report our experience with this procedure. Seven patients (complete type: 5, partial type: 2) underwent this new operation. The diameters of the atrial septal defects were measured by transesophageal echocardiography. The preoperative electrocardiograms were compared with those taken after the operations. Diameters of the atrial defects ranged from 3 to 10 mm. Electrocardiograms before and after the operations did not change. No significant atrioventricular valve regurgitation and no residual shunts were detected by postoperative echocardiography. This method simplifies the repair of atrioventricular septal defects. In the short-term results, no arrhythmia and no valve regurgitation was seen.