Tricuspid dura mater bioprostheses: more than 20-year follow-up of 3 patients.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 11515914.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Replacement of the tricuspid valve is sometimes necessary. We report 3 consecutive patients with tricuspid insufficiency who underwent valve replacement with glycerol-preserved, homologous dura mater cardiac bioprostheses between 1971 and 1973. The first 2 patients are well 28 and 27 years later; the last patient was lost to follow-up after 20 years. We conclude that preservation of homologous dura mater bioprostheses in glycerol may reduce rates of thromboembolism, thrombosis, and structural dysfunction during the late postoperative period.
Medical subject headings
- Bioprosthesis
- Heart Valve Prosthesis
- Tricuspid Valve
- Tricuspid Valve Insufficiency