Coronary stent deployment in situs inversus.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 11602566.
- Also identified by PMC identifier 1729993.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Situs inversus with dextrocardia occurs in approximately one in 10 000 patients. Successful stent deployment for the treatment of unstable angina and situs inversus is presented. Three technical challenges associated with the procedure are highlighted. Firstly, the successful choice of diagnostic and interventional catheters is based on an understanding of the orientation of the aortic arch. With a right sided aorta Judkins catheters should be successful. Secondly, image reversal is not necessarily required for image interpretation. Thirdly, successful coronary engagement with catheters requires rotation in a direction opposite to that normally used.
Medical subject headings
- Coronary Artery Disease
- Situs Inversus
- Stents