Cementless total hip arthroplasty in young Chinese patients: a comparison of 2 different prostheses.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 11607902.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Sixty-one primary cementless total hip arthroplasties were performed in 45 Chinese patients <40 years old. There were 27 Anatomic Medullary Locking (AML, Depuy, Warsaw, IN) prostheses and 34 Porous Coated Anatomic (PCA, Howmedica, Rutherford, NJ) prostheses. The average follow-up was 7.6 years (range, 3-11 years). Ten hips (16%) were reoperated; the reason was polyethylene wear with or without osteolysis in 7 hips. Osteolytic lesion was present in 34 hips (56%). The cumulative successful rate at 10 years was 67% using reoperation for any reason as the endpoint. The cumulative successful rate was 98%, however, if revision for aseptic loosening was used as the endpoint. The 2 prostheses did not show significant differences in most parameters except that the PCA hips had significantly more acetabular loosening (P =.02) and periprosthetic osteolysis (P =.01).
Medical subject headings
- Arthroplasty, Replacement, Hip
- Hip Prosthesis
Anatomy
- hip