Myopotential denoising of ECG signals using wavelet thresholding methods.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 11681756.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We present empirical comparisons of several wavelet-denoising methods applied to the problem of removing (denoising) myopotential noise from the observed noisy ECG signal. Namely, we compare the denoising accuracy and robustness of several wavelet thresholding methods (VISU, SURE and soft thresholding) and a new thresholding approach based on Vapnik-Chervonenkis (VC) learning theory. Our findings indicate that the VC-based wavelet approach is superior to the standard thresholding methods in that it achieves: Higher denoising accuracy (in terms of both MSE measure and visual quality) and more robust and compact representation of the denoised signal (i.e., it uses fewer wavelets).
Medical subject headings
- Action Potentials
- Artifacts
- Electrocardiography
- Heart
- Signal Processing, Computer-Assisted