Glistenings with long-term follow-up of the Surgidev B20/20 polymethylmethacrylate intraocular lens.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 11704044.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To evaluate the incidence and progression of small refractile vacuoles in a consecutive series of patients implanted with the Surgidev B20/20 (Surgidev Corporations, Goleta, California) polymethylmethacrylate intraocular lens. Observational case series. A 4-year prospective study of the progression of glistenings in patients implanted with the Surgidev B20/20 intraocular lenses. In a consecutive series of 51 patients (73 eyes) that received the Surgidev B20/20 intraocular lens onset, number, and location of intraocular lens glistenings, best-corrected visual acuity, and associated ocular pathology were noted. With mean follow-up of 98 +/- 27 months (range, 48 to 176 months), 65 of 73 (89%) eyes had intraocular lens glistenings. Glistenings increased in frequency and size with increasing follow-up (P =.001). Glistenings may occur in polymethylmethacrylate intraocular lenses with long-term follow-up, and they are progressive.
Medical subject headings
- Lenses, Intraocular
- Polymethyl Methacrylate
- Postoperative Complications
- Prosthesis Failure
- Refractive Errors