Minimal 10-year results of a tapered cementless femoral component in total hip arthroplasty.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 11742451.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A series of 120 primary total hip arthroplasties with minimal 10-year follow-up, in which a cementless, proximal-to-distal, dual-tapered geometry femoral component was used, was reviewed. At a mean follow-up interval of 12.20 years, a mean Harris hip score improvement of 38 points was calculated. Three (2.5%) femoral components were revised secondary to aseptic loosening, yielding a 97.5% survivorship. Thigh pain was mild or absent in 96.6% of the cases. Distal femoral osteolysis was observed in <2% of cases. The Harris hip score improvement, low incidence of severe thigh pain, high survivorship, and low incidences of significant stress shielding and distal osteolysis suggest excellent long-term results with the use of this uncemented tapered design, adding credence to the design rationale and justifying its continued use.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Hip Prosthesis
Anatomy
- femur
- hip